UPSEN Professional Power Solution
Search
Search
Confirm
Cancel
upsen
1
2
3
4
1
2
3
4
名称

RT Series UPS 1K-10KVA

● Rack Mount - Tower Convertible. ● Rotate LCD Display. ● Adaptive Load Management. ● Zero delay.
  • Rack Mount - Tower Convertible.
  • Rotate LCD Display.
  • Adaptive Load Management.
  • Zero delay.
Retail price
0.0
USA
Market price
0.0
USA
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
暂时无货
1
Characteristics
Specifications
Downloads

High Frequency Online UPS Rack Tower Star Series RT 1K-10KVA(1Ph in/1Ph out)

 

Key Features:

  • Rack Mount - Tower Convertible.
  • Rotate LCD Display.
  • Active Input Power Factor Correction (PFC), UPS can correct the input power factor. Under full load, the input power factor can reach over 0.95 so that the electric environment of the users will not be polluted.
  • Adaptive Load Management.
  • It sdopts standard frame structure design. The structure is compact.
  • Sine wave output no matters in AC mode or battery mode can provide sine wave power source with low distortion. It provides the best power source guarantee for the load equipments for users.
  • Zero delay: when the utility power is cut off or recover, there is absolutely no time between the transfer of AC mode and battery mode. It effectively ensures the reliability of load operation.
  • Input null line and fire detecting function:it can detect if the null line and fire wire are wrongly connected. It avoids wrong connection of null line and fire wire of UPS AC power input.
  • It has voltage breakthrough protection and strong anti-interference function.

 

Applications

Servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM etc.

MODE(RT Series) RT1K RT1KL RT2K RT2KL RT3K RT3KL RT6KL RT10KL
Input Rated Capacity 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W
Voltage 90 ± 5 ~290 ± 5Vac 176 ~ 276Vac
Current 6A(max) 12A(max) 16A(max) 31A(max) 60A(max)
Frequency 40 ~ 60 Hz
Power factor Conformity EN60555-2(≥0.95) ≥0.95(MAX)
Output Voltage 220Vac ( 1 ± 2%) 220Vac ( 1 ± 1%)
Current 4.55A 9.1A 13.6A 27.3A 54A
Frequency (50 ± 2)Hz (50 ± 1)Hz
Power Factor 0.8 lag
Waveform Sine Wave
Waveform Linear ≤ 7% when RCD 100% loading (Non-line)
Distortion Linear ≤ 3% when RCD 100% loading (line)
Overload protection 105%< <125% → 50s 100%-125%,1 minutes to transfer to bypass;
125%< <150% → 25s >150%,100ms to transfer to bypass
>150% → 300s  
Transfer Time Oms
Type of Battery Sealed lead acid maintenance-free
External Battery Voltage 3*7Ah 36Vdc 6*7Ah 72Vdc 8*7Ah 96Vdc 192Vdc/240Vdc
Working Operating Environment Temperatures() 0-40
Relative Temperature() 0-90(%)
Altitude <1500m
Communication 9pin D trpe comector (RS232)
Size (W*D*H) mm 482*450*88 Standard Type (3U): 482*680*132.5 482*680*132.5
Long Backup Type (2U): 482*450*88
Weight (kg) 14.5 8 22 9.8 26 9.8 20 25
*Specifications are subject to change without prior notice.
Characteristics +

High Frequency Online UPS Rack Tower Star Series RT 1K-10KVA(1Ph in/1Ph out)

 

Key Features:

  • Rack Mount - Tower Convertible.
  • Rotate LCD Display.
  • Active Input Power Factor Correction (PFC), UPS can correct the input power factor. Under full load, the input power factor can reach over 0.95 so that the electric environment of the users will not be polluted.
  • Adaptive Load Management.
  • It sdopts standard frame structure design. The structure is compact.
  • Sine wave output no matters in AC mode or battery mode can provide sine wave power source with low distortion. It provides the best power source guarantee for the load equipments for users.
  • Zero delay: when the utility power is cut off or recover, there is absolutely no time between the transfer of AC mode and battery mode. It effectively ensures the reliability of load operation.
  • Input null line and fire detecting function:it can detect if the null line and fire wire are wrongly connected. It avoids wrong connection of null line and fire wire of UPS AC power input.
  • It has voltage breakthrough protection and strong anti-interference function.

 

Applications

Servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM etc.

Specifications +
MODE(RT Series) RT1K RT1KL RT2K RT2KL RT3K RT3KL RT6KL RT10KL
Input Rated Capacity 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W
Voltage 90 ± 5 ~290 ± 5Vac 176 ~ 276Vac
Current 6A(max) 12A(max) 16A(max) 31A(max) 60A(max)
Frequency 40 ~ 60 Hz
Power factor Conformity EN60555-2(≥0.95) ≥0.95(MAX)
Output Voltage 220Vac ( 1 ± 2%) 220Vac ( 1 ± 1%)
Current 4.55A 9.1A 13.6A 27.3A 54A
Frequency (50 ± 2)Hz (50 ± 1)Hz
Power Factor 0.8 lag
Waveform Sine Wave
Waveform Linear ≤ 7% when RCD 100% loading (Non-line)
Distortion Linear ≤ 3% when RCD 100% loading (line)
Overload protection 105%< <125% → 50s 100%-125%,1 minutes to transfer to bypass;
125%< <150% → 25s >150%,100ms to transfer to bypass
>150% → 300s  
Transfer Time Oms
Type of Battery Sealed lead acid maintenance-free
External Battery Voltage 3*7Ah 36Vdc 6*7Ah 72Vdc 8*7Ah 96Vdc 192Vdc/240Vdc
Working Operating Environment Temperatures() 0-40
Relative Temperature() 0-90(%)
Altitude <1500m
Communication 9pin D trpe comector (RS232)
Size (W*D*H) mm 482*450*88 Standard Type (3U): 482*680*132.5 482*680*132.5
Long Backup Type (2U): 482*450*88
Weight (kg) 14.5 8 22 9.8 26 9.8 20 25
*Specifications are subject to change without prior notice.
Downloads +

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china
  • UPSEN
  • UPSEN
  • UPSEN
    UPSEN
  • UPSEN

    Hotline:
    +86 - (0)755 - 29610051

  • UPSEN