UPSEN Professional Power Solution
Search
Search
Confirm
Cancel
upsen
>
>
>
>
Queen Star Series 33Q 60K - 200KVA
33Q60-200
33Q60-200
名称

Queen Star Series 33Q 60K - 200KVA

● DSP + IGBT technology. ● Output power factor 0.9. ● Active power factor correction in all phases. ● Emergency power off function (EPO).
  • DSP + IGBT technology.
  • Output power factor 0.9.
  • Active power factor correction in all phases.
  • Emergency power off function (EPO).
Retail price
0.0
USD
Market price
0.0
USD
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
暂时无货
1
Characteristics
Specifications
Downloads

Online UPS Queen Star Series 60K-200KVA  (3ph in/3ph out)

 

Key Features:

  • Advanced DSP digital control to make the control system more stableand reliable.
  • Double transform on-line design,adopting power factor coorrection(PFC) technology,input power factor is up to 0.9
  • Output power factor is0.9(0.8is avalable optional),with higher actual load capacity to save users' investiment.
  • Inteligent charging management,±16 - ±20pcs(32-40pcs) batteries to select.
  • Plentiful options,USB or RS485 communication interface, SNMP card (optional),parallel board (optional).
  • ECO working mode,high efficiency and energy saving reduce users'cost.
  • Parallel redundancy function,it enables to connect 4units in paralle,and the battery pack can be shared in parallel.
  • Four modes(three phase three-single phase, single-three phase,single phase)
Model 33Q 60KL 33Q 80KL 33Q 100KL 33Q 120KL 33Q 160KL 33Q 200KL
Rated Power 60KVA/54KW 80KVA/72KW 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW
Input Phase 3 Phase 4Wires and Ground
Rated Voltage 380 / 400 / 415Vac
Voltage Range 208 ~ 478 Vac 3P4W+G
Frequency Range 45 ~ 55Hz (50Hz ) / 54~66Hz (60Hz) (auto sensing)
Power Factor ≥ 0.99
Output Phase 3 Phase 4Wires and Ground
Rated Voltage 380 / 400 / 415Vac (1±1%3P4W+G
Power Factor 0.9 0.9( 1.0 Optional)
Output Frequency Synchronized With Input;
Mains Frequency ≥ Maximum±10%,Output Frequency is 50(±0.2%)Hz;
50/60±0.2%(Battery)
THD ≤2% with Linear Load     /   ≤5% with Non Linear Load
Current Factor 3:1
Output Overload Load≤110%:60mins;   Load≤125%:10 mins;  
Load≤150%:1 min;    Load≥150%shutdown immediately
Efficiency Normal Mode ≥94.5%
Battery Rated Voltage Default ±192VDC
Quantity 32 - 40
Charge Current(A) 20A Max. 24A (Adjustable) 36A (Adjustable) 54A (Adjustable) 54A (Adjustable)
Conversion time between Mains Power and Battery 0ms
Protection ShortCircuit Hold Whole System
Overheat Line Mode: Switch to Bypass;            Backup Mode: Shutdown UPS immediately
BatteryLow Alarmand Switch off
Self-diagnostics up on Power On and Software Control
EPO Shutdown UPS immediately
Battery Advanced Battery Management
NoiseSuppression Complies with EN62040-2
Alarms Audible &Visual Line Failure,Battery Low,Overload, System Fault
ComunicationInterface RS485, RS232 , EPO(Standard) ;
Intelligent slot and SNMP Card(Optional),Relay card(Optional)
Operating Environment Operating Temperature 0 ~ 40
Storage Temperature -25 ~ 55
Audible Noise ≤ 60 dB
Altitude <1500m.   When>1500m,lowerthe rated powerforuse
Humidity  95% non condensing
Dimension Machine Size - W*D*H(mm) 300*865*960 430*1000*1200 600*1000*1200
Net Weight(KG) 85.5 169 249
Gross Weight(KG) 101 189 269
Safety Conformance CE, EN / IEC62040-2, EN / IEC62040-1-1
*Specification are subject to change without prior notice
Characteristics +

Online UPS Queen Star Series 60K-200KVA  (3ph in/3ph out)

 

Key Features:

  • Advanced DSP digital control to make the control system more stableand reliable.
  • Double transform on-line design,adopting power factor coorrection(PFC) technology,input power factor is up to 0.9
  • Output power factor is0.9(0.8is avalable optional),with higher actual load capacity to save users' investiment.
  • Inteligent charging management,±16 - ±20pcs(32-40pcs) batteries to select.
  • Plentiful options,USB or RS485 communication interface, SNMP card (optional),parallel board (optional).
  • ECO working mode,high efficiency and energy saving reduce users'cost.
  • Parallel redundancy function,it enables to connect 4units in paralle,and the battery pack can be shared in parallel.
  • Four modes(three phase three-single phase, single-three phase,single phase)
Specifications +
Model 33Q 60KL 33Q 80KL 33Q 100KL 33Q 120KL 33Q 160KL 33Q 200KL
Rated Power 60KVA/54KW 80KVA/72KW 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW
Input Phase 3 Phase 4Wires and Ground
Rated Voltage 380 / 400 / 415Vac
Voltage Range 208 ~ 478 Vac 3P4W+G
Frequency Range 45 ~ 55Hz (50Hz ) / 54~66Hz (60Hz) (auto sensing)
Power Factor ≥ 0.99
Output Phase 3 Phase 4Wires and Ground
Rated Voltage 380 / 400 / 415Vac (1±1%3P4W+G
Power Factor 0.9 0.9( 1.0 Optional)
Output Frequency Synchronized With Input;
Mains Frequency ≥ Maximum±10%,Output Frequency is 50(±0.2%)Hz;
50/60±0.2%(Battery)
THD ≤2% with Linear Load     /   ≤5% with Non Linear Load
Current Factor 3:1
Output Overload Load≤110%:60mins;   Load≤125%:10 mins;  
Load≤150%:1 min;    Load≥150%shutdown immediately
Efficiency Normal Mode ≥94.5%
Battery Rated Voltage Default ±192VDC
Quantity 32 - 40
Charge Current(A) 20A Max. 24A (Adjustable) 36A (Adjustable) 54A (Adjustable) 54A (Adjustable)
Conversion time between Mains Power and Battery 0ms
Protection ShortCircuit Hold Whole System
Overheat Line Mode: Switch to Bypass;            Backup Mode: Shutdown UPS immediately
BatteryLow Alarmand Switch off
Self-diagnostics up on Power On and Software Control
EPO Shutdown UPS immediately
Battery Advanced Battery Management
NoiseSuppression Complies with EN62040-2
Alarms Audible &Visual Line Failure,Battery Low,Overload, System Fault
ComunicationInterface RS485, RS232 , EPO(Standard) ;
Intelligent slot and SNMP Card(Optional),Relay card(Optional)
Operating Environment Operating Temperature 0 ~ 40
Storage Temperature -25 ~ 55
Audible Noise ≤ 60 dB
Altitude <1500m.   When>1500m,lowerthe rated powerforuse
Humidity  95% non condensing
Dimension Machine Size - W*D*H(mm) 300*865*960 430*1000*1200 600*1000*1200
Net Weight(KG) 85.5 169 249
Gross Weight(KG) 101 189 269
Safety Conformance CE, EN / IEC62040-2, EN / IEC62040-1-1
*Specification are subject to change without prior notice
Downloads +
下一个

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china