UPSEN Professional Power Solution
Search
Search
Confirm
Cancel
upsen
1
2
3
4
1
2
3
4
名称

LS33 Series 10K-200KVA

● True galvanic isolation transformer design. ● Online double-conversion. ● Intelligent battery management to prolong battery lifecycle. ● Accept dual-mains input.
  • True galvanic isolation transformer design.
  • Online double-conversion.
  • Intelligent battery management to prolong battery lifecycle.
  • Accept dual-mains input.
Retail price
0.0
USD
Market price
0.0
USD
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
暂时无货
1
Characteristics
Specifications
Downloads

Low Frequency Online UPS Legend Strar Series LS33 10K-200K(3Ph in/3Ph out)

 

Key Features:

  • Online double-conversion.
  • DSP technology guarantees high reliability.
  • True galvanic isolation transformer design.
  • Control designed to withstand all kinds of loads.
  • Intelligent battery management to prolong battery lifecycle.
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment.
  • Adjustable battery numbers.
  • Accept dual-mains input.
  • Parallel operation with up to 4 units (option).
  • Variety of communication options available.

 

Application:

  • Data center, Industrial equipment, Financial and Securities, Large Data rooms, Postal and Telecommunications, Energy and Electricity, Industrial and Commercial tax affair,Medical and Health.
MODEL LS33 10K LS33 20K LS33 30K LS33  40K LS33 60K LS33 80K LS33 100K LS33 120K LS33 160K LS33  200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hz or 56-64Hz
INVERTER
Nominal Voltage 3 * 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement 120o ±1% (balanced load)
120o ±2% (imbalances 50% of the load)
Dynamic Recovery Time 1 cycle at 98 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:01
Admissible Power Factor 0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load <1%
Current Limit High overload, short-circuit: RMS Voltage Limit
High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC* 16 pcs 12VDC * 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 192 VDC 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 216 VDC 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D*W*H(mm) 656*405* 817 656*405* 941 840*432*1140 975 *554 *1286 1200 *910 *1680 1500 *1140 *1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
* Product specifications are subject to change without further notice
Previous
Characteristics +

Low Frequency Online UPS Legend Strar Series LS33 10K-200K(3Ph in/3Ph out)

 

Key Features:

  • Online double-conversion.
  • DSP technology guarantees high reliability.
  • True galvanic isolation transformer design.
  • Control designed to withstand all kinds of loads.
  • Intelligent battery management to prolong battery lifecycle.
  • Redundant fan design and independent ventilation enhance durable operation under harsh environment.
  • Adjustable battery numbers.
  • Accept dual-mains input.
  • Parallel operation with up to 4 units (option).
  • Variety of communication options available.

 

Application:

  • Data center, Industrial equipment, Financial and Securities, Large Data rooms, Postal and Telecommunications, Energy and Electricity, Industrial and Commercial tax affair,Medical and Health.
Specifications +
MODEL LS33 10K LS33 20K LS33 30K LS33  40K LS33 60K LS33 80K LS33 100K LS33 120K LS33 160K LS33  200K
CAPACITY 10KVA /8KW 20KVA /16KW 30KVA /24KW 40KVA /32KW 60KVA /48KW 80KVA /64KW 100KVA /80KW 120KVA /96KW 160KVA /128KW 200KVA /160KW
INPUT
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Acceptable Voltage Range 305VAC ~ 460VAC
Frequency 46-54Hz or 56-64Hz
INVERTER
Nominal Voltage 3 * 380VAC/400VAC (3Ph + N)
Precision Stationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load)
<5% (Non-linear Load)
Phase Displacement 120o ±1% (balanced load)
120o ±2% (imbalances 50% of the load)
Dynamic Recovery Time 1 cycle at 98 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:01
Admissible Power Factor 0.6~1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load <1%
Current Limit High overload, short-circuit: RMS Voltage Limit
High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
MAINTENANCE BYPASS
Type Without interruption
Voltage 3 * 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency Line Mode 90% 91% 92% 93%
Battery Mode 90% 91% 93% 93%
BATTERY & CHARGER
Battery Type and Numbers 12VDC* 16 pcs 12VDC * 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 192 VDC 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current Max.: 40 A
Charging Voltage 216 VDC 432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D*W*H(mm) 656*405* 817 656*405* 941 840*432*1140 975 *554 *1286 1200 *910 *1680 1500 *1140 *1800
Net Weight (Kgs) 180 205 295 330 451 519 950 1350
* Product specifications are subject to change without further notice
Downloads +
上一个

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china
  • UPSEN
  • UPSEN
  • UPSEN
    UPSEN
  • UPSEN

    Hotline:
    +86 - (0)755 - 29610051

  • UPSEN