Century Star 5
Century Star Series UPS 6-10Kva (2)
Century Star 6
Century Star Series UPS 6-10Kva (1)
Century Star 5
Century Star Series UPS 6-10Kva (2)
Century Star 6
Century Star Series UPS 6-10Kva (1)
名称

Century Star 1K-10KVA

● Output Power Factor PF 1.0 ● Input Power Factor Correction ● Converter Mode Available ● Generator Compatible
  • Output Power Factor PF 1.0
  • Input Power Factor Correction
  • Converter Mode Available
  • Generator Compatible
Retail price
0.0
USD
Market price
0.0
USD
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
暂时无货
1
Characteristics
Specifications
Downloads

High Frequency Online UPS Century Star Series 1K-10Kva (1ph in/1ph out)

Key Features:

  • Ture Double-Conversion
  • Microprocessor Control Optimized Reliability
  • Output Power Factor PF 1.0
  • Settable Charger Current from 1A - 12A Through LCD Screen
  • Configurable Battery Voltage
  • Input Power Factor Correction
  • Wide Input Voltage(110V - 300V)
  • Converter Mode Available
  • Generator Compatible
  • EPO for 6 - 10KVA Model
  • Communication Port SNMP Slot, RS232, USB etc.
Model C1K C1KL C2K C2KL C3K C3KL C6K C6KL C10K C10KL
Redundancy Parallelled & Redundancy
Rated Capacity 1KVA 2KVA 3KVA 6KVA 10KVA
INPUT
Input Formats L + N + PE
Nominal Voltage 208 / 220 / 230 / 240VAC
Input Voltage Range 110 ~ 300VAC
Frequency Range 44 ~ 56Hz or 54Hz ~ 66Hz
Power Factor ≥0.99
Harmonic Distortion ≤3%THD(Linear Load); ≤5% THD(Non-linear Load)
OUTPUT
Output Formats L + N + PE
Output Voltage 208 / 220 / 230 / 240VAC
Voltage Regulation ±1%
Frequency Range Line Mode: Synchronized Range, Battery Mode: 50 / 60Hz ±0.1%
Harmonic Distortion ≤2%THD(Linear Load); ≤5% THD(Non-linear Load) ≤2%THD(Linear Load); ≤4% THD(Non-linear Load)
Power Factor 1.0 1.0
Transfer Time AC Mode to Battery Mode 0ms, Inverter Mode to Bypass Mode 4ms
Overlord Capacity Line Mode:
1min@105%~125% load
30s@125%~150% load
0.5ms@>150% load
Line Mode:
30min@102%~105% load
10min@105%~125% load
30s@125%~150% Load
500ms@>150% load
Line Mode:
10min@102%~105% load
10min@105%~125% load
10s@125%~150% Load
500ms@>150% load
EFFICIENCY
AC Mode Peak Efficiency 93% Peak Efficiency 94% Peak Efficiency 95%
Full Loader Efficiency 90% Full Loader Efficiency 91% Full Loader Efficiency 95%
BATTERY
Numbers 7Ah*2(3) 7Ah*4(6) 7Ah*6(8) 7Ah*16(20) 16~20pcs 7Ah*16(20) 16~20pcs
Typical Recharge Time depending on user needs
Charging Current 1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
ENVIRONMENT
Ambient Temperature 0 ~ 40℃
Humidity 20% ~ 95%(No Condensing)
Storage Temperature -15 ~ 60℃(Battery: 0 ~ 40℃)
Altitude The altitude should not exceed 1000m, and the height above 1000m should bereduced to a maxinmun of 4000m. Rafer to IEC62040
INDICATORS
LCD Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, So On
CERTIFICATION
Certification  
PHYSICAL
Unit Dimension(MM) 350*145*230 410*190*325 410*190*325 500*248*616 500*240*460 500*248*616 500*240*460
Net Weight(KG) 18.6 9 19 10 25 11 57 18 68.5 20
MANAGEMENT
Interface RS232, Intelling Slot Selectable
*Product Specifications are Subject to Change Without Notice.
Characteristics +

High Frequency Online UPS Century Star Series 1K-10Kva (1ph in/1ph out)

Key Features:

  • Ture Double-Conversion
  • Microprocessor Control Optimized Reliability
  • Output Power Factor PF 1.0
  • Settable Charger Current from 1A - 12A Through LCD Screen
  • Configurable Battery Voltage
  • Input Power Factor Correction
  • Wide Input Voltage(110V - 300V)
  • Converter Mode Available
  • Generator Compatible
  • EPO for 6 - 10KVA Model
  • Communication Port SNMP Slot, RS232, USB etc.
Specifications +
Model C1K C1KL C2K C2KL C3K C3KL C6K C6KL C10K C10KL
Redundancy Parallelled & Redundancy
Rated Capacity 1KVA 2KVA 3KVA 6KVA 10KVA
INPUT
Input Formats L + N + PE
Nominal Voltage 208 / 220 / 230 / 240VAC
Input Voltage Range 110 ~ 300VAC
Frequency Range 44 ~ 56Hz or 54Hz ~ 66Hz
Power Factor ≥0.99
Harmonic Distortion ≤3%THD(Linear Load); ≤5% THD(Non-linear Load)
OUTPUT
Output Formats L + N + PE
Output Voltage 208 / 220 / 230 / 240VAC
Voltage Regulation ±1%
Frequency Range Line Mode: Synchronized Range, Battery Mode: 50 / 60Hz ±0.1%
Harmonic Distortion ≤2%THD(Linear Load); ≤5% THD(Non-linear Load) ≤2%THD(Linear Load); ≤4% THD(Non-linear Load)
Power Factor 1.0 1.0
Transfer Time AC Mode to Battery Mode 0ms, Inverter Mode to Bypass Mode 4ms
Overlord Capacity Line Mode:
1min@105%~125% load
30s@125%~150% load
0.5ms@>150% load
Line Mode:
30min@102%~105% load
10min@105%~125% load
30s@125%~150% Load
500ms@>150% load
Line Mode:
10min@102%~105% load
10min@105%~125% load
10s@125%~150% Load
500ms@>150% load
EFFICIENCY
AC Mode Peak Efficiency 93% Peak Efficiency 94% Peak Efficiency 95%
Full Loader Efficiency 90% Full Loader Efficiency 91% Full Loader Efficiency 95%
BATTERY
Numbers 7Ah*2(3) 7Ah*4(6) 7Ah*6(8) 7Ah*16(20) 16~20pcs 7Ah*16(20) 16~20pcs
Typical Recharge Time depending on user needs
Charging Current 1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
1A(Default)
1~12A(Settable)
External Battery Pack
1~12A
(Settable)
ENVIRONMENT
Ambient Temperature 0 ~ 40℃
Humidity 20% ~ 95%(No Condensing)
Storage Temperature -15 ~ 60℃(Battery: 0 ~ 40℃)
Altitude The altitude should not exceed 1000m, and the height above 1000m should bereduced to a maxinmun of 4000m. Rafer to IEC62040
INDICATORS
LCD Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, So On
CERTIFICATION
Certification  
PHYSICAL
Unit Dimension(MM) 350*145*230 410*190*325 410*190*325 500*248*616 500*240*460 500*248*616 500*240*460
Net Weight(KG) 18.6 9 19 10 25 11 57 18 68.5 20
MANAGEMENT
Interface RS232, Intelling Slot Selectable
*Product Specifications are Subject to Change Without Notice.
Downloads +

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china
  • UPSEN
  • UPSEN
  • UPSEN
    UPSEN
  • UPSEN

    Hotline:
    +86 - (0)755 - 29610051

  • UPSEN