Queen Star Series 1K - 3KVA

● 0.9 Power Factor, 1Kva=0.9Kw. ● Large LCD Display. ● Zero power switch delay. ● Active input power factor correction (PFC).
  • 0.9 Power Factor, 1Kva=0.9Kw.
  • Large LCD Display.
  • Zero power switch delay.
  • Active input power factor correction (PFC).
Retail price
0.0
USD
Market price
0.0
USD
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
暂时无货
1
Characteristics
Specifications
Downloads

High Frequency Online UPS Queen Star Series 1K-3Kva (1ph in/1ph out)

 

Key Features:

  • Three Level Inverter Technology
  • Smaller Deisgn
  • Over 94.5% Efficiency
  • Real Time Current Limit Technology
  • DSP Technology.
  • Environment Friendly And eco-designed.
  • Active input power factor correction (PFC).
  • Wide range of input voltage and frequency.
  • Zero power switch delay.
  • Active Load Management.
  • Sufficient Expansion Slots.
  • The load power factor is 0.9.
  • Generator Supportable.
  • Large-screen LCD.
Model Q1K Plus Q1K Q1KL Q2K PLUS Q2KL Q2KL PLUS Q3K PLUS Q3KL Q3KL PLUS
Rating 1KVA/900W 2KVA/1800W 3KVA/2700W
Input
Input System Single phase &earth ground
Voltage Range (90±5)VAC~(300±5)VAC
Power Factor ≥0.99
Voltage Range of Bypass (80±5)VAC~(286±5)VAC(default:80VAC~264VAC Could be adjusted by software)
Output
Output System Single phase &earth ground
Rated Voltage 220/ 230 / 240VAC
Power Factor 0.9(Standard)
Voltage Precision ≤ ±2%
Output Frequency Normal Mode 1.The output frequency synchronizes with the input frequency when the input frequency is in the range of 46 Hz~54 Hz
2. The output frequency is 50Hz when the input frequency is not in the range of 46 Hz~54 Hz
Battery Mode 3.Can be set as 60Hz
Inverter Overload Capacity
(Utility Power,25°
)
105%±5%<Load≤125%±5% 50s transfer to bypass
125%±5%<Load≤150%±5% 25s transfer to bypass
Load>150%±5% 300s transfer to bypass
Transfer Time 0ms(Normal mode → Battery mode)
Normal to battery mode 0ms
Battery to normal mode 0ms
Normal to bypass mode 4ms   with load
Bypass to normal mode 4ms   with load
Crest Factor 3 : 1
Battery
Batteries Voltage 24VDC 36VDC 36VDC 48VDC 48VDC 72VDC 72VDC 72VDC 96VDC
Battery Quantity 2 3 none 4 none none 6 none none
Battery Type Sealed maintenance-freeload-acid battery of battery voltage 12V/7AH
Backup Time(25°) Full load:5-10mins(Standard)
Charge Current 1A 5.5A 1A 5.5A 5.5A 1A 5.5A 5.5A
Physical
Operating Environment Humidity:20%-90%,Temperature:0°C-40C
Machine Size(W*D*H)mm 144*280*230 144*280*230 144*400*230 144*400*230 144*400*230 190*425*328 144*400*230 144*400*230
Net Weight(KG) 8 10 4.5 14 5.4 5.4 19 5.6 5.6
Gross Weight(KG) 8.6 10.6 5.3 14.8 6.2 6.2 20 6.4 6.4
Package Size(W*D*H)mm 245*385*325 245*385*325 245*385*325 245*530*325 245*500*325 245*500*325 295*555*435 245*500*325 245*500*325
*Specification are Subject to Change Without Prior Notice
Characteristics +

High Frequency Online UPS Queen Star Series 1K-3Kva (1ph in/1ph out)

 

Key Features:

  • Three Level Inverter Technology
  • Smaller Deisgn
  • Over 94.5% Efficiency
  • Real Time Current Limit Technology
  • DSP Technology.
  • Environment Friendly And eco-designed.
  • Active input power factor correction (PFC).
  • Wide range of input voltage and frequency.
  • Zero power switch delay.
  • Active Load Management.
  • Sufficient Expansion Slots.
  • The load power factor is 0.9.
  • Generator Supportable.
  • Large-screen LCD.
Specifications +
Model Q1K Plus Q1K Q1KL Q2K PLUS Q2KL Q2KL PLUS Q3K PLUS Q3KL Q3KL PLUS
Rating 1KVA/900W 2KVA/1800W 3KVA/2700W
Input
Input System Single phase &earth ground
Voltage Range (90±5)VAC~(300±5)VAC
Power Factor ≥0.99
Voltage Range of Bypass (80±5)VAC~(286±5)VAC(default:80VAC~264VAC Could be adjusted by software)
Output
Output System Single phase &earth ground
Rated Voltage 220/ 230 / 240VAC
Power Factor 0.9(Standard)
Voltage Precision ≤ ±2%
Output Frequency Normal Mode 1.The output frequency synchronizes with the input frequency when the input frequency is in the range of 46 Hz~54 Hz
2. The output frequency is 50Hz when the input frequency is not in the range of 46 Hz~54 Hz
Battery Mode 3.Can be set as 60Hz
Inverter Overload Capacity
(Utility Power,25°
)
105%±5%<Load≤125%±5% 50s transfer to bypass
125%±5%<Load≤150%±5% 25s transfer to bypass
Load>150%±5% 300s transfer to bypass
Transfer Time 0ms(Normal mode → Battery mode)
Normal to battery mode 0ms
Battery to normal mode 0ms
Normal to bypass mode 4ms   with load
Bypass to normal mode 4ms   with load
Crest Factor 3 : 1
Battery
Batteries Voltage 24VDC 36VDC 36VDC 48VDC 48VDC 72VDC 72VDC 72VDC 96VDC
Battery Quantity 2 3 none 4 none none 6 none none
Battery Type Sealed maintenance-freeload-acid battery of battery voltage 12V/7AH
Backup Time(25°) Full load:5-10mins(Standard)
Charge Current 1A 5.5A 1A 5.5A 5.5A 1A 5.5A 5.5A
Physical
Operating Environment Humidity:20%-90%,Temperature:0°C-40C
Machine Size(W*D*H)mm 144*280*230 144*280*230 144*400*230 144*400*230 144*400*230 190*425*328 144*400*230 144*400*230
Net Weight(KG) 8 10 4.5 14 5.4 5.4 19 5.6 5.6
Gross Weight(KG) 8.6 10.6 5.3 14.8 6.2 6.2 20 6.4 6.4
Package Size(W*D*H)mm 245*385*325 245*385*325 245*385*325 245*530*325 245*500*325 245*500*325 295*555*435 245*500*325 245*500*325
*Specification are Subject to Change Without Prior Notice
Downloads +

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china