Line Interactive UPS Amber Star Series 1K-5KVA (1ph in/1ph out)

 

Key Features:

  • Wide range of input voltage.

The UPS can offer normal and stable service voltage under its input voltage range.When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.

  • Wide range of AVR(Automatic voltage regulation).

In the product's input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.

  • Automatic self detection when UPS on(LED).

Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode.

  • Silence function.

In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.

  • Overload protection.

In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.

  • Short circuit protection.

When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.

  • The low current switch.

This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.

  • Automatic charging.

There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.

Model A1K A1.5K A2K A3K A1KL A1.5KL A2KL A3KL A5KL
Capacity (VA) 1000VA 1500VA 2000VA 3000VA 1000VA 1500VA 2000VA 3000VA 5000VA
Capacity (W) 700W 1050W 1400W 2100W 700W 1050W 1400W 2100W 3500W
Display LCD
AC Mode
Input voltage range 145~275Vac
Input frequency 50Hz (48Hz-54Hz)
Output voltage range 200~240Vac
Efficienty ≥ 96% (AC mode)
Inverter Mode
Output voltage range 220Vac±5%
Output frequency 50±0.5Hz
Output wave form Pure sine wave
Transfer time Typical 2~6ms, Max.10ms.
Overload capability Automally shut down in 60sec while with 110% load, and shut down in 5sec while with 120% load
BATTERY
QTY & capacity of battery 2 pc* 12V7Ah 2 pc* 12V9Ah 4pcs* 12V7Ah 4pcs* 12V9Ah External batteries(24V), capacity depends on user's choice. External batteries(48V), capacity depends on user's choice.
Charging period 6~8 hours recover to 90% capacity Depends on the batteries connected.
Charging current 2-5A 6-15A
MANAGEMENT
USB Optional
PROTECTION
PROTECTIONS 1. Auto re-starts when AC recovers
2. Automatic charging (offline charging)
3. Battery low voltage protection
4. Overload & Short circuit protection
5. Over current protection (Breaker for AC mode; System automaticlly shut down wihin 20ms in Inverter mode).
PHYSICAL
Unit dimension (mm) 405*145*220 455*195*330 405*145*220 455*195*330
Net weight (1pc, kg) 23.8 25.6 30.2 34.5 19.8 21.4 26.6 32.7 41.5
*Specifications change without further notice
Next
Characteristics +

Line Interactive UPS Amber Star Series 1K-5KVA (1ph in/1ph out)

 

Key Features:

  • Wide range of input voltage.

The UPS can offer normal and stable service voltage under its input voltage range.When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.

  • Wide range of AVR(Automatic voltage regulation).

In the product's input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.

  • Automatic self detection when UPS on(LED).

Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode.

  • Silence function.

In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.

  • Overload protection.

In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.

  • Short circuit protection.

When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.

  • The low current switch.

This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.

  • Automatic charging.

There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.

Specifications +
Model A1K A1.5K A2K A3K A1KL A1.5KL A2KL A3KL A5KL
Capacity (VA) 1000VA 1500VA 2000VA 3000VA 1000VA 1500VA 2000VA 3000VA 5000VA
Capacity (W) 700W 1050W 1400W 2100W 700W 1050W 1400W 2100W 3500W
Display LCD
AC Mode
Input voltage range 145~275Vac
Input frequency 50Hz (48Hz-54Hz)
Output voltage range 200~240Vac
Efficienty ≥ 96% (AC mode)
Inverter Mode
Output voltage range 220Vac±5%
Output frequency 50±0.5Hz
Output wave form Pure sine wave
Transfer time Typical 2~6ms, Max.10ms.
Overload capability Automally shut down in 60sec while with 110% load, and shut down in 5sec while with 120% load
BATTERY
QTY & capacity of battery 2 pc* 12V7Ah 2 pc* 12V9Ah 4pcs* 12V7Ah 4pcs* 12V9Ah External batteries(24V), capacity depends on user's choice. External batteries(48V), capacity depends on user's choice.
Charging period 6~8 hours recover to 90% capacity Depends on the batteries connected.
Charging current 2-5A 6-15A
MANAGEMENT
USB Optional
PROTECTION
PROTECTIONS 1. Auto re-starts when AC recovers
2. Automatic charging (offline charging)
3. Battery low voltage protection
4. Overload & Short circuit protection
5. Over current protection (Breaker for AC mode; System automaticlly shut down wihin 20ms in Inverter mode).
PHYSICAL
Unit dimension (mm) 405*145*220 455*195*330 405*145*220 455*195*330
Net weight (1pc, kg) 23.8 25.6 30.2 34.5 19.8 21.4 26.6 32.7 41.5
*Specifications change without further notice
Downloads +
下一个

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china
  • UPSEN
  • UPSEN
  • UPSEN
    UPSEN
  • UPSEN

    Hotline:
    +86 - (0)755 - 29610051

  • UPSEN