Blue Star Series 10K-40KW

● Low DC Voltage, Saving System Cost. ● Various Communication Ports and Remote Controls ● RS232 / RS485 / APP / SNMP / GSM Optional ● Support Generator Connection
  • Low DC Voltage, Saving System Cost.
  • Various Communication Ports and Remote Controls
  • RS232 / RS485 / APP / SNMP / GSM Optional
  • Support Generator Connection
Retail price
0.0
USD
Market price
0.0
USD
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
暂时无货
1
Characteristics
Specifications
Downloads

Pure Sine Wave Inverter Blue Star Series 10K-40KW (1ph in / 1ph out)

 

Key Features:

  • Pure Sine Wave Output.
  • Low DC Voltage, Saving System Cost.
  • AC Charge Current 0-45A Adjustable.
  • Wide LCD Screen, Clearly and Precisely Shows Icon Data.
  • 100% Imbalance Loading Design, 3 Times Peak Power.
  • Setting Different Working Modes Based on Variable Usage Requirements.
  • Optional Setting for DC or AC Mode Priority
  • Various Communication Ports and Remote Controls
  • RS232 / RS485 / APP / SNMP / GSM Optional
  • Support Generator Connection
  • Wide Input Range and AVR Output
  • Optional Choice to Add Built-in PWM or MPPT Controller
Model BS10K BS12K BS15K BS20K BS25K BS30K BS40K
Rated Power 10KW 12KW 15KW 20KW 25KW 30KW 40KW
Battery Rated Volatage 96 / 192 / 216 / 240VDC 192 / 216 / 240VDC 216 / 240VDC 240VDC 384VDC
Charge Current Max 15A
Input Voltage Range 85VAC - 137VAC / 170VAC - 275VAC
Frequency 45-65HZ
Output Voltage Range Inverter Output: 110VAC / 115VAC / 120VAC / 220VAC / 230VAC / 240VAC ± 2%
Mains Output: 110VAC / 115VAC / 120VAC / 220VAC / 230VAC / 240VAC ± 10%
Frequency Inverter Output: 50 / 60HZ ± 1%;    Mains Output: Automatic Track
Effciency ≥85%(80% Resistive Load)
Output Waveform Pure Sine Wave
Conversion Time ≤4ms (Typical Load)
Mode DC Mode / AC Mode
Display LCD
Communication RS232
Cooling Method Temperature Control Fan Cooling
Protection Overload / Overcurrent / Short Circuit / Over Temperature
Temperature -10℃ - 40℃
Noise ≤55dB
Machine Size: L*W*H(mm) 485*300*646 600*300*800 720*435*1120
Package Size:  L*W*H(mm) 545*360*770 660*360*925 780*495*1245
Net  Weight (kg) 66 105 108 113 123 135 160
Gross Weight (kg) 77 118 121 130 138 150 180
Optional: Add Built-in PWM controller  (Model NO. Blue Star Plus Series)
Rated Current 50A / 100A / 150A / 200A
Input Voltage Range 96V: 120 - 200VDC;        192V: 240 - 350VDC;     216V: 270 - 400VDC;     240V: 300 - 450VDC
Maximum Input Power 50A (96V:5KW;    192V:10KW;    216V:11KW;    240V:12KW;    384V:20KW)
100A (96V:10KW;    192V:20KW;    216V:22KW;    240V:24KW;    384V:40KW)
150A (96V:15KW;    192V:30KW;    216V:33KW;    240V:36KW;    384V:60KW)
200A (96V:20KW;    192V:40KW;    216V:44KW;    240V:48KW;    384V:80KW)
*Product specification are subject to change without further notice.
Characteristics +

Pure Sine Wave Inverter Blue Star Series 10K-40KW (1ph in / 1ph out)

 

Key Features:

  • Pure Sine Wave Output.
  • Low DC Voltage, Saving System Cost.
  • AC Charge Current 0-45A Adjustable.
  • Wide LCD Screen, Clearly and Precisely Shows Icon Data.
  • 100% Imbalance Loading Design, 3 Times Peak Power.
  • Setting Different Working Modes Based on Variable Usage Requirements.
  • Optional Setting for DC or AC Mode Priority
  • Various Communication Ports and Remote Controls
  • RS232 / RS485 / APP / SNMP / GSM Optional
  • Support Generator Connection
  • Wide Input Range and AVR Output
  • Optional Choice to Add Built-in PWM or MPPT Controller
Specifications +
Model BS10K BS12K BS15K BS20K BS25K BS30K BS40K
Rated Power 10KW 12KW 15KW 20KW 25KW 30KW 40KW
Battery Rated Volatage 96 / 192 / 216 / 240VDC 192 / 216 / 240VDC 216 / 240VDC 240VDC 384VDC
Charge Current Max 15A
Input Voltage Range 85VAC - 137VAC / 170VAC - 275VAC
Frequency 45-65HZ
Output Voltage Range Inverter Output: 110VAC / 115VAC / 120VAC / 220VAC / 230VAC / 240VAC ± 2%
Mains Output: 110VAC / 115VAC / 120VAC / 220VAC / 230VAC / 240VAC ± 10%
Frequency Inverter Output: 50 / 60HZ ± 1%;    Mains Output: Automatic Track
Effciency ≥85%(80% Resistive Load)
Output Waveform Pure Sine Wave
Conversion Time ≤4ms (Typical Load)
Mode DC Mode / AC Mode
Display LCD
Communication RS232
Cooling Method Temperature Control Fan Cooling
Protection Overload / Overcurrent / Short Circuit / Over Temperature
Temperature -10℃ - 40℃
Noise ≤55dB
Machine Size: L*W*H(mm) 485*300*646 600*300*800 720*435*1120
Package Size:  L*W*H(mm) 545*360*770 660*360*925 780*495*1245
Net  Weight (kg) 66 105 108 113 123 135 160
Gross Weight (kg) 77 118 121 130 138 150 180
Optional: Add Built-in PWM controller  (Model NO. Blue Star Plus Series)
Rated Current 50A / 100A / 150A / 200A
Input Voltage Range 96V: 120 - 200VDC;        192V: 240 - 350VDC;     216V: 270 - 400VDC;     240V: 300 - 450VDC
Maximum Input Power 50A (96V:5KW;    192V:10KW;    216V:11KW;    240V:12KW;    384V:20KW)
100A (96V:10KW;    192V:20KW;    216V:22KW;    240V:24KW;    384V:40KW)
150A (96V:15KW;    192V:30KW;    216V:33KW;    240V:36KW;    384V:60KW)
200A (96V:20KW;    192V:40KW;    216V:44KW;    240V:48KW;    384V:80KW)
*Product specification are subject to change without further notice.
Downloads +

Related products

There is currently no content to display
Please add data record on website background.

Messages

 

If you have any good suggestions and opinions for our company, or want to consult our products, please fill in the form below, we will contact you at the first time!

Username used for comment:
客户留言
Description:
wx wx wx wx wx

Messages

Username used for comment:
客户留言
Description:
© 2020 Shenzhen UPSEN Electronic CO., Ltd. All rights reserved. 粤ICP备20055719号 made-in-china
  • UPSEN
  • UPSEN
  • UPSEN
    UPSEN
  • UPSEN

    Hotline:
    +86 - (0)755 - 29610051

  • UPSEN